Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!utgpu!water!watnot!watmath!clyde!rutgers!husc6!seismo!rick From: rick@seismo.UUCP Newsgroups: comp.unix.wizards Subject: Re: software density select with tc13 & fuji 2444-ac Message-ID: <43153@beno.seismo.CSS.GOV> Date: Fri, 13-Mar-87 16:43:39 EST Article-I.D.: beno.43153 Posted: Fri Mar 13 16:43:39 1987 Date-Received: Sat, 14-Mar-87 10:17:15 EST References: <43125@beno.seismo.CSS.GOV> <2019@cit-vax.Caltech.Edu> Sender: rick@seismo.CSS.GOV Organization: Center for Seismic Studies, Arlington, VA Lines: 12 Summary: Its "always" a driver problem.... I finally got our TC13/Fuji244 to do remote density select. The major problem was that the TC13 ONLY looks at the density select bit IMMEDIATELY after the controller has been reset (e.g. with addr->ts_ssr =0). Once you figure this out (its not documented and Emulex doesn't tell you about it) "all" you have to do is change the ts11 driver to do a controller reset when setting the characteristics. Diffs for this will be in comp.bugs.4bsd in a few days (as soon as I verify that I havent' broken the driver on a real ts11) --rick