Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!watmath!clyde!rutgers!sri-spam!ames!ucbcad!ucbvax!gmr.com!ROY From: ROY@gmr.com.UUCP Newsgroups: mod.computers.vax Subject: Another Excelan question... Message-ID: <8701300905.AA26904@ucbvax.Berkeley.EDU> Date: Fri, 30-Jan-87 04:06:10 EST Article-I.D.: ucbvax.8701300905.AA26904 Posted: Fri Jan 30 04:06:10 1987 Date-Received: Sat, 31-Jan-87 06:05:33 EST Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 27 Approved: info-vax@sri-kl.arpa I know there are quite a few Excelan installations out there from the number of responses to recent messages--hopefully someone can shed some light on a new problem with our Excelan board/EXOS software--specifically when using TELNET. We had the board installed on a VAX 11/785 with no problems. Last weekend, we had it moved to a different 11/785 in the cluster. No software move was involved--just starting it up in a different section of startup. Now the problem...Monday a.m. users started complaining of *random* transposed characters and garbage on the screen when using TELNET to get to the suns or hypercube. It happens whether the user is hard-wired, DECNETed, or attached through broadband SYTEK to the VAX CPU. We have checked the cabling to the board (DEC field service says it looks fine), and have tried re-installing and linking the driver. The board should have the same address on both systems, so that is not a problem. We are out of ideas and getting ready to order a replacement board. Does anyone have any experience with a problem like this or even any suggestions?? Thanks- Lynette Roy GM Research Labs Warren, MI 313/986-1379 CSNET ADDRESS: ROY@GMR.COM or ROY@GMR.CSNET