Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!watmath!clyde!rutgers!mit-eddie!genrad!decvax!ucbvax!XEROX.COM!"Thomas_W._Taylor.WBST147" From: "Thomas_W._Taylor.WBST147"@XEROX.COM.UUCP Newsgroups: mod.computers.vax Subject: Re: Lost Magnetic Tape problem Message-ID: <870204-152506-1214@Xerox> Date: Wed, 4-Feb-87 18:24:45 EST Article-I.D.: Xerox.870204-152506-1214 Posted: Wed Feb 4 18:24:45 1987 Date-Received: Sat, 7-Feb-87 10:37:16 EST Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 13 Approved: info-vax@sri-kl.arpa A similar problem occurred on one of our systems on VMS 3.something, but was supposed to be fixed in VMS 4. I haven't run the test to see if it is really fixed. If I correctly remember the scenario it went something like this: A (SYSTEM) user with a high default priority (9 if I recall corectly) logged off the system while the tape was still mounted and allocated. The rundown of the process and deallocation of devices was out of sync up so the device still thought it was owned by the high priority process. The work-around, of course, is not to have a high priority job or to dismount and/or deallocate before logging off. Is this the cause of your problem? twt