Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!mnetor!seismo!rutgers!jvnca!njitsc1!bob From: bob@njitsc1.njit.edu (Bob Michie) Newsgroups: comp.periphs Subject: Re: Help with Teletype Model 43 Message-ID: <159@njitsc1.njit.edu> Date: Wed, 24-Jun-87 08:46:43 EDT Article-I.D.: njitsc1.159 Posted: Wed Jun 24 08:46:43 1987 Date-Received: Fri, 26-Jun-87 04:39:56 EDT References: <603@gec-mi-at.co.uk> Reply-To: bob@njitsc1.UUCP (Bob Michie) Organization: New Jersey Institute of Technology, Newark NJ Lines: 21 In article <603@gec-mi-at.co.uk> steve@gec-mi-at.co.uk (Steve Lademann) writes: >We're having some problems with a Model 43 Teletype which we have recently >acquired, minus its manual. Now, I don't even know if it's RS232 - does anyone >know how to tell? Also, the 'alarm' light seems to be permanentlty lit, no >matter what we do - is there something we're not doing (like looping some pins >on the interface) Its been along time since i used a TTY43. There was several reasons the alarm light would be on. But the one that was the most frequent was: - There is a switch under the cover which detects if the top is open. Most of the problem i had was with that switch. All is did was to put some tape over it. If there is a problem with the status on the RS232 interface the terminal will stay in local mode and not go online. ------------------------------------------- bob@njitsc1.njit.edu Bob Michie rutgers!andromeda!argus!njitsc1!bob Networking Specialist NJ Institute of Technology