Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!mnetor!uunet!husc6!cmcl2!rutgers!ucla-cs!zen!ucbvax!MIMSY.UMD.EDU!smb From: smb@MIMSY.UMD.EDU (Steve M. Burinsky) Newsgroups: comp.lsi Subject: MOSIS Spice parameters Message-ID: <8709102152.AA05876@mimsy.umd.edu> Date: Thu, 10-Sep-87 17:52:22 EDT Article-I.D.: mimsy.8709102152.AA05876 Posted: Thu Sep 10 17:52:22 1987 Date-Received: Sat, 12-Sep-87 10:42:13 EDT Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 6 If I'm not mistaken, the way MOSIS derives Spice parameters for a given run is to adjust various model parameters to fit parametric curves from devices on the test structures. Thus, the parameters they distribute may have very little in common with those of the actual devices on a given run -- they just happen to produce similar parametric curves.