Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: utzoo!mnetor!uunet!husc6!cmcl2!nrl-cmf!ames!ucbcad!ucbvax!NCSC.ARPA!vtcf From: vtcf@NCSC.ARPA (Williams) Newsgroups: comp.os.vms Subject: DF112 modem and DMF32 controllers Message-ID: <8711041539.AA02221@ncsc.ARPA> Date: Wed, 4-Nov-87 10:39:38 EST Article-I.D.: ncsc.8711041539.AA02221 Posted: Wed Nov 4 10:39:38 1987 Date-Received: Tue, 10-Nov-87 07:21:29 EST Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 16 A while back I asked about a problem I was having trying to dial out on a DF112 moddem using the SET HOST/DTE/DIAL... command. Rummaging through the release notes, it says that this won't work on a DMF-32. The problem is that the modem sends a response character to the host when it detects a carrier signal, but the DMF-32 drops any input until it sees the carrier signal. The release notes state that a workaround is to modify the example in SYS$EXAMPLES:DTE_DF03.MAR to perform a IO$_SENSEMODE!IO$M_RD_MODEM $QIO to check for a carrier signal. I know nothing about MACRO, so this d doesn't help me. I asked someone here who knows MACRO, and he tried to do this, but I get an access violation. Has anyone done this before? ALSO, what's the difference between a DF03 and a DF112? Any help will be greatly appreciated. Thanks in advance Tom Williams vtcf@ncsc.arpa