Xref: utzoo comp.unix.xenix:2007 comp.dcom.modems:1740 Path: utzoo!utgpu!water!watmath!clyde!ima!spdcc!dyer From: dyer@spdcc.COM (Steve Dyer) Newsgroups: comp.unix.xenix,comp.dcom.modems Subject: throughput using CTS flow control on a Trailblazer+ Message-ID: <871@spdcc.COM> Date: 16 Apr 88 18:41:36 GMT Reply-To: dyer@spdcc.COM (Steve Dyer) Organization: S.P. Dyer Computer Consulting, Cambridge MA Lines: 19 I'm using a Telebit Trailblazer+ on one of my dialin ports, fixed at 19.2kb using hardware flow control (gettydefs has EXTA and CTSFLOW defined). I'm finding that effective UUCP throughput ranges between 80-100 bytes per second when a UUCP neighbor without a Trailblazer dials in at 2400 baud, completely negating any benefit of the neighbor's >1200 baud speed. The CTS light seems to blink on every SD (send data) blink. People who dial in to this line at 2400 baud also report jerkiness (although this seems to be hidden and not observable at 1200 baud.) Note we don't appear to be losing data; the low transfer rate isn't due to retransmissions, but due to (excessive?) throttling of the output stream. Any ideas of what to try? /Steve -- Steve Dyer dyer@harvard.harvard.edu dyer@spdcc.COM aka {ihnp4,harvard,husc6,linus,ima,bbn,m2c}!spdcc!dyer