Path: utzoo!attcan!uunet!husc6!bbn!uwmcsd1!ig!agate!ucbvax!utorphys.BITNET!SYSRUTH From: SYSRUTH@utorphys.BITNET Newsgroups: comp.os.vms Subject: RE: dmf32 dip switches Message-ID: <8804192059.AA03744@gpu.utcs.toronto.edu> Date: 19 Apr 88 21:57:00 GMT Sender: daemon@ucbvax.BERKELEY.EDU Organization: The Internet Lines: 41 Assuming you mean the three on the distribution panel: Switch settings for asynch. lines 0 and 1 S1 and S2 Local term. Modems and H3248 SW 1 OFF OFF SW 2 ON ON SW 3 OFF OFF SW 4-7 ON ON SW 8 ON OFF SW 9-10 ON ON Switch setups for synch. line S3 Modems and H3248 (Loopback) SW 1-3 ON SW 6-10 Not Used DMF32 Device Config. S3 Active Device(s) SW 4 SW 5 ON ON Asynch. OFF ON Asynch, LP32 ON OFF Asynch, parallel, synch. OFF OFF Asynch, LP32, synch. This manual is dated 1984, but I don't think the DMF-32 has changed much since then :-). Ruth Milner Systems Manager University of Toronto Physics -------