Path: utzoo!utgpu!attcan!uunet!tektronix!tekcae!vice!michaele From: michaele@vice.ICO.TEK.COM (Michael Enkelis) Newsgroups: comp.dcom.modems Subject: Re: Everex problem (redundant) Message-ID: <2712@vice.ICO.TEK.COM> Date: 28 Jul 88 18:00:43 GMT References: <11100001@uxh.cso.uiuc.edu> <890@oswego.Oswego.EDU> Reply-To: michaele@vice.ICO.TEK.COM (Michael Enkelis) Organization: Tektronix, Inc., Beaverton, OR. Lines: 22 The everex is good for most things, BUT NOT FOR UNIX DIALIN use!! I have one, and if someone call at any speed other than 2400 baud the modem will "lock" at 1200/300 baud and forget 2400 baud compleatly. When I called support they said "oh yea, well we fixed that in the MNP version, want to buy that now???". I said forget it!! At this time i hardwired DTR inside the modem to the RESET pin of the 8031 control computer, and at least i can get 2400 baud back on hangup but not without UNIX complaining about not being able to flush the tty buffers (UNIX wait 2 second's after DTR activate, but the modem takes 3 seconds to self-test after DTR is released. I plan on adding a one-shot to the reset from DTR signal) Now if the would fix the program in EPROM, that would be great, i would spend the $50 or so they might charge for the new chip, but untill then FORGET useing the everex for a answer modem. -- _ _ _ __ ' ) ) ) / /) / ` / /) Michael Enkelis / / / o _. /_ __. _ // /-- __ /_ _ // o _ tektronix!vice!michaele / ' (_(_(__/ /_(_(_(<_(/_ (___, /) )_/ <_(<_(/_(_/_)_ (503) 627-4099