Xref: utzoo comp.os.vms:8389 comp.sys.dec:769 Path: utzoo!utgpu!water!watmath!clyde!att!osu-cis!tut.cis.ohio-state.edu!mailrus!ames!elroy!suned1!efb From: efb@suned1.UUCP (Everett F. Batey II) Newsgroups: comp.os.vms,comp.sys.dec Subject: LATCP Servers (MOM$LOAD) Summary: To chose the boot host Keywords: DS200, MV_2, LATCP Message-ID: <544@suned1.UUCP> Date: 1 Sep 88 03:19:22 GMT References: <8808311604.AA01461@ucbvax.Berkeley.EDU> Reply-To: suned1!efb@elroy.jpl.NASA.Gov (Everett F. Batey II) Distribution: na Organization: NSWSES, Port Hueneme, CA Lines: 20 I have 2 MicroVax 2s (MV2A and MV2B). Originally MV2A was alone and first fed my DS200s their boot loads. Later I added MV2B. I thought I had made MV2B the boot host, until today when MV2A was off line from the ethernet. I could not reboot a DS200 server till MV2A returned. All noticeable conditions and parameters from SYSGEN (conn LTA0/NOADAPT), NCP, LATCP, the DSVCONFIG.DAT databases in MOM$LOAD and the binaries are alike. The file protections look the same. The servers, afterboot hold the AA-..-..-..-..-.. number of MV2A in the SHOW SERVER STATs or whichever it is that shows where the server booted. The clincher that PROVES I DONT KNOW WHAT I AM DOING is when in NCP I attempt to TRIGGER or LOAD NODE server_name VIA QNA-0. When I do so from MV2A, I get no errors; when I try from MV2B, I get NML... error messages which I think pertained to line or circuit. Would greatly appreciate some bright ideas. -- suned1!efb@elroy.JPL.Nasa.Gov sun!tsunami!suned1!efb efbatey@NSWSES.ARPA Any statements / opinions made here are mine, alone, not those of the United States, the DoD, the Navy, the Congress, the Judiciary, nor ...