Xref: utzoo comp.graphics:3572 comp.sys.hp:1215 Path: utzoo!attcan!uunet!ncrlnk!ncrcae!hubcap!gatech!uflorida!haven!adm!smoke!gwyn From: gwyn@smoke.BRL.MIL (Doug Gwyn ) Newsgroups: comp.graphics,comp.sys.hp Subject: Re: Need to direct drive hpp7585B from VAX-VMS 4.6 Message-ID: <8830@smoke.BRL.MIL> Date: 9 Nov 88 10:58:51 GMT References: <10261@ihlpa.ATT.COM> Reply-To: gwyn@brl.arpa (Doug Gwyn (VLD/VMB) ) Organization: Ballistic Research Lab (BRL), APG, MD. Lines: 10 In article <10261@ihlpa.ATT.COM> tfilm@ihlpa.ATT.COM (Lindenmeyer) writes: > We are trying to operate a hp 7585B plotter directly H-P traditionally uses poor judgement in implementing its RS-232-C interfaces. I suspect the plotter in question drops DTR in an attempt to flow-control (even if you ask for DC3/DC1 flow control); with a bit of experimentation you may be able to figure out a good way to hot-wire the handshaking signal lines. Even then you will probably have trouble; let us know if you find a way to use one of these plotters at a high baud rate. (We never did get our 7550A to work entirely right.)