Path: utzoo!attcan!uunet!husc6!mailrus!ames!pasteur!agate!ucbvax!RADC-TOPS20.ARPA!GUBBINS From: GUBBINS@RADC-TOPS20.ARPA (Gern) Newsgroups: comp.sys.zenith.z100 Subject: Re: Z100 disk drive problem, Please Help Message-ID: <12448373370.8.GUBBINS@RADC-TOPS20.ARPA> Date: 21 Nov 88 18:37:14 GMT References: <857@speedy.mcnc.org> Sender: daemon@ucbvax.BERKELEY.EDU Organization: The Internet Lines: 11 If the A: drive is okay, then the controller is fine and the drive is probably out of alignment. If you replaced the timming PLL or 4 phase clock chip on the controller, the timming trim pots may need to be tweeked to recalibrate the timming (B: may be more sensistive). The calibration is detailed in the Z-100 Tech Manual and requires a 'scope, frequency counter, and a voltmeter. The Heath Kit version has a calibration board that I have never seen that does it with only a voltmeter (so I am told... Info, anyone???). Gern -------