Path: utzoo!utgpu!watmath!clyde!att!osu-cis!tut.cis.ohio-state.edu!rutgers!bpa!cbmvax!vu-vlsi!dsinc!lgnp1!phile From: phile@lgnp1.LS.COM (Phil Eschallier) Newsgroups: comp.unix.xenix Subject: Re: Telebit TrailBlazer-Plus Summary: telebit S51 register Keywords: Xenix TBIT modems Message-ID: <521@lgnp1.LS.COM> Date: 16 Dec 88 12:24:06 GMT References: <4137@turnkey.TCC.COM> Organization: Lagniappe Systems -- Norristown PA Lines: 12 In article <4137@turnkey.TCC.COM>, sandy@turnkey.TCC.COM (Sanford 'Sandy' Zelkovitz) writes: > > One other question, I have noticed that SCO set register S51 to 254; however, > my manual reflects that the only allowable settings are 0-5 and 255. I > changed register S51 to 254 and did notice a difference. Basically, since > this must be an undocumented setting, what does it do? > S51 = 254 cause the incoming calls to default to 19200 baud (between the modem and serial card) instead of 9600 (when S51=255). phil eschallier