Path: utzoo!utgpu!attcan!uunet!bywater!acheron!clarke From: clarke@acheron.UUCP (Ed Clarke) Newsgroups: comp.sys.ibm.pc.rt Subject: Re: Hardware Flow Control under AIX 2.2 Message-ID: <409@acheron.UUCP> Date: 25 Dec 88 15:42:37 GMT References: <275@beartrk.UUCP> Distribution: na Lines: 49 I'm having good results with a TB+ and an IBM 4port buffered card. Here are my TB+ settings: E0 F1 M0 Q4 T V1 X3 Version BA4.00 S00=001 S01=001 S02=043 S03=013 S04=010 S05=008 S06=010 S07=060 S08=002 S09=006 S10=007 S11=070 S12=050 S45=255 S47=004 S48=000 S49=000 S50=000 S51=005 S52=002 S53=000 S54=003 S55=000 S56=017 S57=019 S58=000 S59=000 S60=000 S61=045 S62=003 S63=001 S64=001 S65=001 S66=001 S67=000 S68=255 S90=000 S91=000 S92=000 S95=002 S100=000 S101=000 S102=000 S104=000 S110=001 S111=030 S112=001 S121=000 The specs (from devices) for port 1 of a buffered card: tt vt100 ae delay dvam 1 (modem) aa true rts 19200 ixp true (xon/xoff) bpc 7 nosb 1 pt even om dtr sns false The BNU Devices entry for the TB+: ACU tty0 - 19200 telebit \D The BNU Dialers entry for the TB+: telebit =W "" \d\r\c "" ATQ0V1E0M1S50=0S6=7\r\c OK \pATDT\T\r\c CONNECT And a sample Systems entry from an archive site: sir-alan Any ACU 19200 (814)337-0894 "" \r gin:-\K-gin:-\K-gin:-\K-gin: pdsrc In addition to BNU/uucp and news (patchlevel 14), I run PCOMM 1.0 with this setup. My dialing command is "ATS95=0DTW". This turns off the MNP protocol because it causes problems with the non MNP modem that I usually talk to. This system is locked at 2400 on the other end and 19200 on my end. I have no problems sending massive (100-400k) files through the connection using the 'YMODEM' protocol. I do not set S111 to support YMODEM ( it remains at 30 to support UUCP 'g'). -- Ed Clarke uunet!bywater!acheron!clarke