Xref: utzoo comp.dcom.modems:3278 comp.mail.uucp:2692 Path: utzoo!utgpu!attcan!uunet!lll-winken!lll-lcc!ames!pasteur!ucbvax!ucsd!orion.cf.uci.edu!oberon!bbn!mit-eddie!killer!texbell!merkin!hack From: hack@merkin.cactus.org (Greg Hackney) Newsgroups: comp.dcom.modems,comp.mail.uucp Subject: Re: Problems with HDB uucp xfer Message-ID: <579@merkin.cactus.org> Date: 27 Jan 89 03:29:15 GMT References: <257@utgard.UUCP> Reply-To: hack@merkin.cactus.org (Greg Hackney) Distribution: na Organization: Grand Prairie, Texas Lines: 12 In article <257@utgard.UUCP> chris@boris.UUCP (Chris Anderson) writes: >I'm having a problem using HDB uucp with a Telebits TB+. Whats >happening is that connection is made fine, initial protocol exchanges >are done, file names to be sent are exchanged, directories are made, >... then while waiting for the first packet, uucp says 'alarm 1', >'alarm 2', etc. all the way to 'alarm 10', then quits. For what it's worth, I saw the same symptoms when calling rutgers' Telebits. Turned out that the flow control had to be set to "hardware" rather that XON/OFF when speaking with them. -- Greg