Xref: utzoo misc.consumers:8320 comp.dcom.modems:3290 Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!ames!xanth!ukma!rutgers!att!alberta!ubc-cs!van-bc!rsoft!frank From: frank@rsoft.UUCP (Frank I. Reiter) Newsgroups: misc.consumers,comp.dcom.modems Subject: Re: Follow-up on Packard Bell 2400 Keywords: ATX0 Message-ID: <25@rsoft.UUCP> Date: 29 Jan 89 17:11:00 GMT References: <107@ncrmud.Columbia.NCR.COM> Reply-To: frank@rsoft.UUCP (Frank I. Reiter) Organization: Reiter Software Inc., British Columbia Canada Lines: 10 The problem you describe with the PB200 not recognizing a carrier when calling out is a faithful reproduction of a bug in the Hayes 2400. If the X option is set to recognize busy signals then the modem will not respond to a carrier unless it hears a RING first. Note that if neither end times out they will connect after 30 or 40 seconds. -- *=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=* Frank I. Reiter \ / UUCP: {uunet,ubc-cs}!van-bc!rsoft!frank Langley, British Columbia / \ BBS: Mind Link @ (604)533-2312 *=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*