Path: utzoo!attcan!utgpu!watmath!clyde!att!ulysses!smb From: smb@ulysses.homer.nj.att.com (Steven M. Bellovin) Newsgroups: comp.dcom.lans Subject: Re: Cabling beteen BNC T-connector and workstation?! Message-ID: <11359@ulysses.homer.nj.att.com> Date: 23 Mar 89 01:05:22 GMT References: <3036@uvacs.cs.Virginia.EDU> Organization: AT&T Bell Laboratories, Murray Hill Lines: 12 In article <3036@uvacs.cs.Virginia.EDU>, rwl@uvacs.cs.Virginia.EDU (Ray Lubinsky) writes: } A previous poster was mentioning a "fly-run" from a thin Ethernet T-connector } to the machine. Are there any gurus who can comment on the legitimacy of } attempting this? It isn't legit. } I'd gotten the impression that you were forced to attach the T directly to the } workstation and that any extra length between the T and the machine would } seriously degrade performance (by throwing off collision detection). You are correct.