Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!ames!amdahl!pacbell!hoptoad!peora!rtmvax!tarpit!libcmp!root From: root@libcmp.UUCP (Super user) Newsgroups: comp.dcom.modems Subject: Re: Telebit transfer rate problem Summary: S111 Register Incorrectly Configured Message-ID: <221@libcmp.UUCP> Date: 20 Mar 89 01:31:51 GMT References: <640@island.uu.net> Organization: Liberty Computers, Inc., Orlando, FL. Lines: 18 You may wish to check the settings of your "S111" register, if both TELEBIT's are configured for S111=255, then you have failed to select a valid Protocol. The TELEBIT which is acting as the originator needs to select a protocol, i.e. S111=30, and the unit which is answering the call will then configure for the same protocol if S111=255 on that unit. I have noted that the PEP connection without a protocol is at least 20% less efficient. I suggest that you configure your dialer to select a protocol for dial out contacts, and leave your S111=255 to handle incomming calls. Ed Unrein (peora!rtmvax!libcmp!ecu) Liberty Computers, Inc. (407) 293-6346 office voice number UNIX guest account (407) 299-6947 TELEBIT (8N1) login: guest UUCP: libcmp Any (speed any) 14072996947 ogin:-""-ogin:-""-ogin:nuucp