Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!tut.cis.ohio-state.edu!cs.utexas.edu!uunet!mcvax!ukc!icdoc!qmc-cs!miclon!tkc From: tkc@miclon.UUCP (Dr. Tony K. W. Chau) Newsgroups: comp.dcom.lans Subject: TCP/IP connection breaking over Multiple DEC LAN Bridges Keywords: TCP, ethernet, LAN Bridges Message-ID: <261@miclon.UUCP> Date: 24 Apr 89 16:12:30 GMT Organization: Micrognosis International, London. Lines: 15 Dear Newsgroup, I am experience TCP/IP connection being broken (around once a day) when the connection is in an idle state (i.e. no data is going through). The connection is made between a Sun 386i and a Spider system terminal server through 5 DEC LAN Bridges. I checked the ethernet for errors and none of the interfaces registered any errors. I would be most grateful if anyone has any ideas or experience on this one. Many thanks. Tony K. W. Chau Micrognosis, London. (kwchau@uk.ac.ucl.cs (ARPANET) or ...!mcvax!ukc!miclon!tkc )