Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!tut.cis.ohio-state.edu!rutgers!netsys!len From: len@netsys.COM (Len Rose) Newsgroups: u3b.tech,comp.sys.att Subject: Re: Want info on SCSI terminators Summary: Info here.. Keywords: terminator scsi 3B2 Message-ID: <13238@netsys.COM> Date: 21 Apr 89 04:18:59 GMT References: <1099@vsi.COM> Reply-To: len@netsys.COM (Len Rose) Followup-To: u3b.tech Distribution: comp Organization: Netsys,Inc. Lines: 13 The connector is a 3M 3425-6650 or equivalent. All signals must be terminated with 220 ohms to +5 volts and 330 ohms to ground at each end of the cable. All signals are open collector or tri state driven. Len -- len@netsys.com {ames,att,rutgers}!netsys!len