Path: utzoo!utgpu!jarvis.csri.toronto.edu!rutgers!att!mcdchg!mcdhup!greggy From: greggy@mcdhup.UUCP (Gregg Yedwab) Newsgroups: comp.dcom.modems Subject: Re: uucico for TB+ modem Summary: Register problems for Telebit 19200 outgoing Keywords: 19200 baud Message-ID: <142@mcdhup.UUCP> Date: 16 May 89 16:57:11 GMT References: <48@wells.UUCP> Distribution: na Organization: Motorola Microcomputer Division, Hauppauge, NY Lines: 18 In article <48@wells.UUCP>, edw@wells.UUCP (Ed Wells) writes: > I have a Telebit 19200 baud modem that has been online for close > to a year now. I'm very pleased with the modem except that I can't > get it running faster that 9600 baud on a dialout. It appears that > SCO can't support 19200 baud. I was told that they had a Telebit > patch, but after ordering it, I found that it supported the extra > Telebit commands, but not anything faster than 9600 baud. Try this for dialing out: tbfast =W-, "" AT "" AT OK ATS92=0S50=255DT\T "" \d\d\d\d\d\d\d\d CONNECT\sFAST The register combination of s92 followed by s50 should solve problem. -- Gregg Yedwab @ Motorola Microcomputer Division, Hauppauge, N.Y. 11788 UUCP: {rutgers, mcdchg, hplabs!motsj1} mcdhup!greggy Voice: 516-361-7000 I represent merely myself!