Path: utzoo!attcan!utgpu!jarvis.csri.toronto.edu!rutgers!ukma!tut.cis.ohio-state.edu!ucbvax!hplabs!hpfcdc!rjn From: rjn@hpfcdc.HP.COM (Bob Niland) Newsgroups: comp.sys.hp Subject: Re: Getting HP 9000/825 with Mux 98196A to work with TB+ Message-ID: <5570187@hpfcdc.HP.COM> Date: 19 May 89 12:57:00 GMT References: <857@ecf.toronto.edu> Organization: HP Ft. Collins, Co. Lines: 6 re: "...also tried the cable as suggested in the HP Multiplexer manual." Try using an HP 92219Q cable. This cable is the only pre-fab cable I know of that converts the default DCE pinouts of the MUX to DTE for modem use. Bob Niland ARPA:rjn%hpfcrjn@hplabs.HP.COM UUCP:[hpfcse|hplabs]!hpfcla!rjn