Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!umich!samsung!brutus.cs.uiuc.edu!psuvax1!psuvm!CORNELLC!MTG From: MTG@CORNELLC.BITNET (Mike Garcia) Newsgroups: bit.listserv.notis-l Subject: Re: Public Access Terminals & CICS 1.7... Message-ID: Date: 6 Feb 90 16:53:05 GMT Sender: NOTIS/DOBIS discussion group list Reply-To: NOTIS/DOBIS discussion group list Lines: 17 Approved: NETNEWS@PSUVM Gateway In-Reply-To: Message of Tue, 6 Feb 90 10:31:24 CST from >HELP! Under CICS 1.6.1, our public access terminals would come-up to the > LUIS introductory screen when CICS production was brought up... now >under CICS 1.7, this has stopped working and requires clearing the 'CICSVS' >goodmorning message screen and typing in the 'LU__' transaction before getting >the intro screen... can anyone shed any light upon this matter, because nothin >was changed in regards to what NOTIS says to do to make this work??? > >thanks Paul Vitko (university of minnesota) 612-626-1835 Check with your systems programming staff, it sounds like your TCT (Terminal Control Table) is not right. The public access terminals should have GMMSG=NO,TRANSID=LU__ and the appropriate OPERSEC= for you installation. If your shop is using autoinstall for your TCT, the fix may require some special coding by your support people. Mike Garcia Cornell University