Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!umich!samsung!brutus.cs.uiuc.edu!wuarchive!psuvax1!psuvm!UFPINE!WOOGIE From: WOOGIE@UFPINE.BITNET Newsgroups: bit.listserv.novell Subject: Re: Novell & Zenith Expanded Memory Message-ID: Date: 6 Feb 90 12:23:00 GMT Sender: Novell LAN Interest Group Reply-To: Novell LAN Interest Group Lines: 18 Approved: NETNEWS@PSUVM Gateway Original_To: JNET%"novell@suvm" Thanks to everyone who offered suggestions. I am now able to use qemm.sys. I set the switches as follows: device=qemm.sys fr=d000 on ma=2 ha=32 nv ns x=c000-cfff x=e000-e7ff x=b000-b7ff Most of these switches came from the local Zenith rep. However, the real problem I have had is that, for some reason, if the packet driver is loaded higher in memory than the ems driver, then nothing seems to work. Originally, I was loading the packet driver like this: wd8003e 0x60 0x3 0x280 0xd000 and qemm at c800. I have since switched this and all works fine now. Thanks again for the help. Mike