Path: utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!rice!sun-spots-request From: tek@cs.ucla.edu (Ted Kim (Random Dude)) Newsgroups: comp.sys.sun Subject: jumpers Keywords: Hardware Message-ID: <4489@brazos.Rice.edu> Date: 27 Jan 90 20:42:33 GMT Sender: root@rice.edu Organization: Sun-Spots Lines: 15 Approved: Sun-Spots@rice.edu X-Sun-Spots-Digest: Volume 9, Issue 14, message 13 of 14 If you have a 3/460, 3/470, 3/480, you should note an error in: Sun 3400 CPU Board Configuration Manual (PN 813-2055-11, Rev A 15 May 1989) The 3-4 jumper in J2100 (at N-19 on the board), should be IN and should be factory installed that way. (In the manual, it says this jumper is reserved, should be OUT and is factory installed that way.) If it's not in, the CPU board will be happy and pass all self-tests, but won't find a SMD4 controller. Ted Kim UCLA Computer Science Department Internet: tek@penzance.cs.ucla.edu 3804C Boelter Hall UUCP: ...!{uunet|ucbvax}!cs.ucla.edu!tek Los Angeles, CA 90024 Phone: (213) 206-8696