Path: utzoo!utgpu!jarvis.csri.toronto.edu!cs.utexas.edu!uwm.edu!zaphod.mps.ohio-state.edu!rpi!crdgw1!sixhub!davidsen From: davidsen@sixhub.UUCP (Wm E. Davidsen Jr) Newsgroups: comp.unix.xenix Subject: Re: uucp gettydefs for unix systems Keywords: UUCP Message-ID: <464@sixhub.UUCP> Date: 6 Feb 90 02:27:57 GMT References: <680@boink.UUCP> Reply-To: davidsen@sixhub.UUCP (bill davidsen) Organization: *IX Public Access UNIX, Schenectady NY Lines: 18 In article <680@boink.UUCP> root@boink.UUCP (Super user) writes: | | I have tried without success to come with up a gettydefs entry for | SCO Xenix 2.3.2 that will allow generic logins from normal UNIX sites. Most | sites assume 7E1, where the Xenix default is 8N1. 8N1 is the correct default for SysV. BSD sites should set no parity in the L.sys file before calling. I *think* the magic work is P_NONE, but please look it up. Sixhub gets calls from 34 sites, so I think it's fair to say that it works. You now need BREAK to autobaud, the 2.2 getty seemed to shift from a higher to lower speed in RETURN, but the 2.3 version doesn't. I'd scrap the "improvement" if I didn't need dialout on the same line. -- bill davidsen - sysop *IX BBS and Public Access UNIX davidsen@sixhub.uucp ...!uunet!crdgw1!sixhub!davidsen "Getting old is bad, but it beats the hell out of the alternative" -anon