Path: utzoo!utgpu!jarvis.csri.toronto.edu!cs.utexas.edu!tut.cis.ohio-state.edu!ucbvax!USCN.BITNET!Li From: Li@USCN.BITNET (LI Jialin, UGA Physics) Newsgroups: sci.electronics Subject: Error message #50 on HP LaserJet+ Message-ID: <900221021008311.AOCJ@205FE.USCN.UGA.EDU> Date: 21 Feb 90 07:10:39 GMT Sender: daemon@ucbvax.BERKELEY.EDU Lines: 50 I have a LaserJet+(call it LJ No.1) needed a new fusing roller, so I bought one from HP and replaced it myself. However it does not work. I than took the whole thing(everything on fig.A) off, put it on another LaserJet+(call it LJ No.2), it worked. Place it back to LJ No.1, still wouldn't work. After a while I remembered that when error #50 first time come up on LJ No.1 was because the connection of fusing bulb was open (but after I connect it, the error #50 keeped coming up anyway). I did waite 7 min before every power up, and did reset the AC Circuit Break on the AC power supply. While tring to find out why, I unintentionally reproduced the err #50 on LJ No.2, and the reason is the same: disconnect the AC power supply to fusing bulb. Here is how I did it: ============================================================================ LaserJet+ No.2, works fine AC thermo-protector AC (Note: | [O] [OO] thermistor | thermo- | .----------------------------------------------------. | protector | : ___________________________________________ : | wired in |-------|___________________________________________|------| seires w/ : fusing bulb : fusing `----------------------------------------------------' bulb) fusing roller fig.A ============================================================================= Power off, disconnect one side of the fusing bulb AC thermo-protector AC | [O] [OO] thermistor | | .-----------------------------------------------------. | | : ___________________________________________ : | |----\ \-|___________________________________________|------| : fusing bulb : `-----------------------------------------------------' fusing roller Turn power on, error #50. fig.B ============================================================================ Power off, reconnect it (as fig.A), wait more than 7min, power on. It passed self test, and waited for 90sec, error message #50. Now I have both printers dead and need anyone's help badly. Thanks for any help in advance. Jialin