Path: utzoo!utgpu!jarvis.csri.toronto.edu!rutgers!cs.utexas.edu!uunet!pride386!terry From: terry@pride386.UUCP (Terry Lyons) Newsgroups: comp.unix.xenix Subject: Re: SCO UNIX & Mylex CPU Summary: roms Keywords: Serial port mess Message-ID: <210@pride386.UUCP> Date: 5 Mar 90 07:30:42 GMT References: <1729@lakesys.lakesys.com> Distribution: usa Organization: Pride Plastics Inc., Buena Park, CA Lines: 17 In article <1729@lakesys.lakesys.com>, deanr@lakesys.lakesys.com (Dean Roth) writes: > > The problem: > ----------- > > I have a Mylex 386 25MHz CPU with ESDI disk > and SCO UNIX 3.2. The OS insists the system > has an Arnet 8 port serial board on COM1 & COM2. > This is no Arnet controller in it, never has been. Call Mylex I had the same thing the answer is there are 1 or 2 chips that HAVE to be changed to run xenix (which they will gladly do) once that is done its warp speed (by the way once you get it going check and see if the battery powered clock works..please let me know) mine didn't work UNTIL we had a page fault error (think idleout is the culprit)