Path: utzoo!utgpu!jarvis.csri.toronto.edu!cs.utexas.edu!tut.cis.ohio-state.edu!uc!nic.MR.NET!shamash!tank!mimsy!chris From: chris@mimsy.umd.edu (Chris Torek) Newsgroups: comp.unix.wizards Subject: Re: UDA50 on VAX 11/730 Keywords: UDA50 Message-ID: <22946@mimsy.umd.edu> Date: 7 Mar 90 05:40:00 GMT References: <4764@vice.ICO.TEK.COM> Organization: U of Maryland, Dept. of Computer Science, Coll. Pk., MD 20742 Lines: 21 In article <4764@vice.ICO.TEK.COM> michaele@vice.ICO.TEK.COM (Michael Enkelis) writes [edited to bare essentials]: >uda0: soft error, SDI error, unit 0, event 053, hdr 0x0 >uda0: soft error, SDI error, unit 0, event 0113, hdr 0x0 >uda0: hard error, SDI error, unit 0, event 0113, hdr 0x0 These are, in order: sdi command timeout drive error (soft) ctlr detected protocol drive error (soft) ctlr detected protocol drive error (hard) This indicates a problem in the controller (uda50 or equivalent), drive, or cabling between the two. >4.3 BSD UNIX #5: Fri Feb 16 23:27:28 PST 1990 Convert to 4.3BSD-tahoe; you will get a much better UDA/RA driver. -- In-Real-Life: Chris Torek, Univ of MD Comp Sci Dept (+1 301 454 7163) Domain: chris@cs.umd.edu Path: uunet!mimsy!chris